In Stock

کد کالا:3be16590c2e2

Relay 8 Channels 16 Amps

RLY-8ch-16A

RLY-8ch-16A controller,  it used to control the lighting channels or shutter motors (Max 16 Amps per channel) , suitable for high load circuit. it can be Programmed manually for lighting channels, or by PC for advanced scene setting . also it has access holes for its mechanical relay to switch on each channel by hand in case of emergency network failure.

Important Features

–  Strong latching green relay each 16Amps.

–  Mechanical switch for each relay for emergency turning ON/OFF.

–  Can be used to control 4 different shutters or motors.

–  Can Be programmed manually with TIS panels. 

–  Low consumption Products (15mA/24VDC Normal Running)

–  Include 8 built in scenes and sequences,

–  LED for network life and for each channel indicator .

–  Working with TIS bus protocol

–  ABS anti-flame case.

–  UL USA  certified relay, terminal, ICs and PCB.

–  Product CE certified.

TIS Latching Relay

8 Channels 16 Amps

Model: RLY-8CH-16A

Data Sheet Rev 1.4

 

Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Failure to observe the instructions may cause damage to the device and other hazards.

These instructions are an integral part of the product, and must remain with the end customer.           

Basic information

This device is a product of the TIS system. It is a DIN-rail mountable device with 8 independent free voltage Relay channels which can be controlled separately with TIS protocol messages, technical knowledge obtained in TIS training courses is a prerequisite to proper understanding how to install device. Basic Manual Programming can be done without the software. Advanced Programming knowledge about software obtained in the advanced training courses.

 

Intended use

Control lighting, curtains, Motors e.g. light on/off, shades open/close, Motor, Pumps, scene, and sequence.

 

Product characteristics

 

Outputs

Number of channels

Nominal voltage

Nominal current per channel

Maximum total channels load

 

8

0 – 230 V AC 50/60 Hz

16 A / 230 VAC

128 A / 230 VAC

Output switching current

Max switching current

 

Max Continues current 

Max. switching Voltage:

 

50A/230 VAC Resistive

20A/230 VAC florescent

20A/230 VAC

440VAC

Output service life

Mechanical service life

 

> 10,000,000 Times

 

Output switching times

Operating and releasing

Max. operating frequency

15mS (at nomi. Volt)

20 cycle/min

 

TIS Bus

Number of devices on 1 line

Bus voltage

Current consumption (Normal)

Current consumption (operation)

Protection

 

Max. 64

12-32 V DC

<12 mA / 24 V DC

<35 mA / 24 V DC

Reverse Polarity Protection

Reaction time

 

 

approx. 20ms

Operating and display elements

Programming button/LED

1-8 buttons

Switch position display

By TIS bus

Programming

Upgrading

 

For assignment of the physical address

Manually ON/OFF and Programming

Relay emergency operator

TIS Protocol massages and commands

Manual basic Prog, or by software.

1 X mini USB for up to date upgrading.

Mounting 

Din Rail

Wall mount

 

Standard 35 mm Din rail

screw holder on the back of the module

Connection terminal

Load and Power

Data / bus

 

Screw terminal  0,25…4mm2

Male female connectors Link + screw Terminal

Functions 

Lighting control ON/OFF Dimming

Curtain control

Scenes

Sequences

 

8 channel controlled separately

Can set 4 group of curtain (open/close) option

8 different scenarios

8 different sequences

Weight

Without packaging

 

0.45 KG

Dimensions

Width x length x height

 

91mm x 145mm x 75mm

Housing

Materials

Casing color

Button color

IP rating

ABS anti fire

Black Gray

Silver

IP 20

Temperature range

Operation

Storage

Transport

 

   0…60°C

-20…50°C

-25…75°C

Air humidity

 

<85% non-condensing

 

                                                                                                                            

 

 

Wiring diagram

Data connection

TIS Bus connection can be done by 2 ways

 

 

  • A- Train Connector

By attaching 2 modules or more with each other on the Din rail

B-Screw terminals connection

By using the Cat5e cable to connect to TIS bus 4 terminals (24V,D+, D-, GND) 

 

Recomanded UTP cat5e color connection

24V –  Orange

D+   –  Blue

D-    –  White Blue

GND – White Orange

Electrical wire Connections: 

Input Phase:

1.5 or 2.5 mm electrical wire.

Load connection (1-8) :

1.5 or 2.5 mm electrical wire.

Warranty

We provide a warranty as provided for by law.

Hologram warranty seal and product serial number is provided by each device.

Please send the description of the defect with Product S/N to our dealer network.

 

info@tissmarthome.com

www.tissmarthome.com

 

 

Your custom content goes here. You can add the content for individual product
[vc_row layout="ts-row-wide" el_class="fix-column-no-margin"][vc_column width="1/3"][ts_single_image img_url="http://demo.theme-sky.com/images/Gon/product-detail-banner1.png" link="#" style_effect="eff-border-scale" target="_self"][/vc_column][vc_column width="1/3"][ts_single_image img_url="http://demo.theme-sky.com/images/Gon/product-detail-banner2.png" link="#" style_effect="eff-border-scale" target="_self"][/vc_column][vc_column width="1/3"][ts_single_image img_url="http://demo.theme-sky.com/images/Gon/product-detail-banner3.png" link="#" style_effect="eff-border-scale" target="_self"][/vc_column][/vc_row]
بازگشت به بالا